![]() |
|||
|
|
|||
|
|
|||
Medical Ambulance/Evacuation/Mass Casualty Bus MAB Product specified is: MAB - Medical Ambulance/Triage/Evacuation/Mass BASIC VEHICLE DIMENSIONS Width: Interior 90" Height: Interior 78" Length: Exterior 39’-09" Wheelbase: 234" Departure Angle: 8 degrees Break-Over Angle: 8 degrees Turning Radius: Curb – 33’08” Wall – 38’08”
MAB CHASSIS SPECIFICATIONS Air Cleaner: Shall be heavy-duty replaceable type. Air cleaner shall be mounted outside the passenger compartment with proper ducting to provide adequate engine aspiration. Location of the air intake shall be above the radiator for cleanest possible air. The air cleaner shall be readily accessible for servicing. The air cleaner shall include an air restriction indicator. Donaldson disposable single stage air cleaner or approved equal. Alternator: Shall be 12 volt/320 amp and provide at least 50% of the rated charge at engine idle. Axles: Front: 14,000 lb capacity. I-Beam type with Needle Bearing-King pin size 1.92" diameter with sealed bushing and tapered roller thrust bearings. Turning angle shall be minimum 45° to allow maximum maneuverability. Rear: Heavy Duty. 23,000 lbs. Capacity single reduction, spiral bevel gearing. Gear Ratio shall be so that vehicle can maintain a road speed of 65 MPH. GVWR of the Front and Rear axles shall large enough to properly handle the weight requirements of a 22 stretchered passenger Medical Ambulance/Evacuation Bus application. Batteries: Triple GRP 31 with top mounted threaded studs. There shall be a Minimum of 650 cold cranking amps per battery at 0 degree. A master battery cut-off switch shall be provided within easy reach of the Driver. Battery box shall be located aft of left front wheel. Exterior door shall have a security lock keyed the same as the fuel door lock. Brakes: System designed to meet all requirements of FMVSS-121 in effect at time of manufacture. Antilock Brakes: Air Brakes: Cooling System: Cruise Control: Vehicle shall have cruise control. Drive Line: Heavy-duty with safety guard to prevent shaft from whipping through the floor or dropping to the ground in the event of failure. Engine Compartment: Shall be a durable, lightweight fiberglass interior engine cover. There shall be a separate access door located in the cover for access to all engine fluid fill and checks without opening the engine cover. The engine cover shall not exceed 11" from the body floor at the rear and shall not extend more than 36" from the dash. The engine cover shall provide a highly effective seal with thermal and acoustic insulation. The top of the engine cover shall include a diamonette metal step tread for durability. Exhaust System: Diesel Particulate Filter (DPF) with Diesel Oxidation Catalyst between the engine end DPF with 6" tailpipe exiting left side in front of rear axle. Rustproofing: All chassis framing, fasteners, and suspension system are to be painted with a rust inhibiting paint after assembly and before body mounting. Shock Absorbers: Heavy duty direct acting double action piston type. 2 front and 2 rear. Springs/Suspension: Front: Heavy-duty taper leaf type (parabolic leaf), rated at a minimum of 6,600 lbs. each side front. Springs to be mounted inboard to provide at least 45 degree turn angle. Rear: Heavy-duty Air-Ride suspension shall be provided. The two air springs shall have two parabolic trailer arms with rubber bushings for lubrication free maintenance. Suspension capacity shall be 23,000GVW. Rear Air suspension shall be equipped with a rear dump valve for the purpose of kneeling the rear of the bus upon loading and unloading of stretcher patients. Steering: Integral full power Ross TAS-65 120.42:1 ratio with tilt and telescoping 18" 2 spoke padded steering wheel. Tires: Single front and dual rear. Goodyear or Michelin 11R x 22.5 - 14 Ply Tires. Transmission: Allison EVS3000 Transmission. The electronically controlled transmission includes integral oil filter and dash mounted push button selector. A diagnostic data reader connection is easily accessible under the dash. The shift control permits shifting five (5) forward speeds with driver selectable performance or economy shift schedules. A remote mounted electronic control unit. Transmission fluid shall be Transynd Synthetic. Wheels: Steel disc type 8.25 x 22.5 10 hole hub piloted wheels. 1-piece size to fit tire selected. Front and rear wheels shall have stainless steel wheel covers. Wiring: Color coded and numbered. Wiring harness enclosed in protective convoluted conduit. Wiring shall be protected by a manual resetting circuit breaker.
MAB BODY SPECIFICATIONS: Air Horn: Dual Trumpet Roof Mounted. Backing Alarm: A backing alarm shall be provided that sounds whenever the vehicle is in reverse. 112DB minimum. Backing Camera: Backing camera has a 6” color LCD monitor with sound. Battery Mounting: Skirt mounted battery box. 13” High x 25 ½” Wide x 15 1/2 ” Deep. Steel roller (ball bearing type) slides and slide out tray. Front: Shall be chrome and shall be a minimum of 9 12" high after forming with a minimum section modulus of .5369 square inches for added strength. Cell Phone Power Outlets: 12v plug in style outlets for cellular telephone or other 12v equipment power shall be located within easy reach of the driver and each of the attendant seats. Construction: The bus body shall be constructed of prime commercial quality 20 gauge steel. The bus body shall be constructed to meet or exceed all state and federal requirements in effect at the time of manufacture. The internal skeletal structure is welded. Roof Bows: The roof bow frame assembly shall consist of 14 gauge hat section bows extending from the bottom of floor line on one side to the other. Bow frames shall be continuous, one-piece, 14 gauge rolled channel hat sections 1 ½ " deep, mounted on 27" centers to provide a rollbar type protection.
Floor: The floor shall be constructed of 14 gauge “C” channels forming an “I” beam crossmember every 9". These “I” beam crossmembers shall be equal to a 9-gauge thickness at the floor sill and shall extend the full width of the flat floor area and shall be designed so as not to trap moisture. All floor crossmembers shall be welded to 16 gauge rail, which extend the entire length of the body floor on each side. This floor bumper shall also serve as the interior seat rail, to be used for mounting seats. This floor bumper shall be welded at each point of intersection with the body bows.
Cowl steps: Two (2) heavy-duty folding steps located on the front bumper. One-inch protection closed, four inch in open position. Slotted Tread in 2 1\8" by 4 3\8"step base for sure foot. Color: Exterior polyurethane paint, International Winter White #9219. Optional colors available. Defrosters: Defrosters shall be sufficient in capacity to keep windshield clear of fog, snow, and ice. Unit to have full-length windshield defroster channel for supplying hot air to windshield. Door: Rear Loading Rear loading door shall be of sufficient size to accommodate stretcher patients to be carried through and into the bus. Minimum Dimensions shall be approximately 36”W x 71”H. Door is split upper type with pneumatic shocks to hold top portion of door in the open position for loading of patients. Door shall have a locking mechanism that locks the door in the open position to prevent the door from closing while vehicle is being loaded or unloaded Drip Molding: Threaded through bows the entire length of vehicle to form a roll cage. Electrical: Access- Main body wiring harness is fully accessible thru removable raceways, removable shelves and access panels on driver's side of vehicle. Wiring harness is protected by manual reset circuit breakers. Wiring is color coded and numbered and flame retardant. The main vehicle electrical junction box is located below the driver's window and accessible from the exterior thru a hinged door with locking exterior release. A Wiring diagram is attached to back side of electrical access door. Floor Construction: Floor constructed of 14-gauge galvanized steel C channels forming an I-beam cross-member every 9" equal to 10-gauge thickness and shall extend full length of body. Crossmembers shall also extend the full width if body except at the wheelhouse area. All floor cross-members are to be welded to a 14 gauge steel floor channel bumper extending completely around the outside edge of floor construction. This bumper is also to be welded at each point of intersection with body bows. There shall be a marine grade plywood sub-floor of a nominal 5/8". Altro “Chroma” 2.7mil series floor covering only. Color shall be Mineral TFCR 2730. Fuel Tank Opening: Generator Compartment: Graphics: Lettering and graphics cost shall be included in this bid. Heater & Defrosters: Lights/Exterior: Headlights - Dual seal beam (Halogen). Head lights shall have wig wag switch capability. Front Directional- (2) 7" round LED amber All lights comply with FMVSS 108. All exterior emergency lighting shall comply with NFPA 1901 standards. Map Light: (1) flexshaft map light located over the driver. Mirrors: Interior- 6" x 30" safety glass with rubber edges Mirrors: Exterior- Heated remote control transit mirrors.
Mounting: Bus body shall be mounted to chassis frame in such a manner as to prevent shifting. Body and lock tab mounting bracket. Rubber mounting pads reinforced with fiber shall be used to cushion the body on the chassis at every floor crossmember. Mud Flaps: Rubber mud flaps front and rear. Mud Guards: Reinforced steel mud guards front and rear of all wheels from floor to bottom of skirt. Paneling: Exterior Roof The roof panels are to be double, 20 gauge zinc-coated steel, riveted to each body bow frame. The roof sheets are pieced in (3) sections, (2) laterally, (1) lengthwise over seams. All roof sheets are to be sealed to prevent leaks. Each bus shall be completely water tested for assurance of no leaks. Roof shall be reinforced with (2) 16 gauge crash rails applied externally, riveted through roof panels and into roof bows to give extra strength in overhead area. Exterior panels shall be primed both sides before assembly. Paneling: Exterior Exterior panels shall be primed both sides before assembly for rust prevention. The exterior side panels shall be at least 20-gauge sheet steel, riveted to both flanges of the roof bows. Reflectors: (3) on each side and (2) on rear. Roof Escape Hatches: Optional - (2) two roof escape hatches Hatches are capable of opening fore or aft to allow air to enter or exit the vehicle. Rub Rails: Two aluminum rub rails with rubber inserts. One located below regular window line and the other located at the floor line. Rubber Fenderettes: (4) Installed at each wheelhouse opening. Seat: Driver Deluxe air operated high back driver’s seat with side armrest. Driver seat belt is to be integrated into the seat. Seat will move aft and fore, up and down. Seat shall also have air operated lower lumbar support. Transit blue color Service Access Openings: Service Access Openings shall be provided for access to the following components: Engine access door for servicing, engine oil, transmission fluid and power steering fluid without removing the engine cover. Left and right front hinged panels for access to wiper motors, heater filters, washer reservoir, and electrical components. Center front access panel door - removable without tools to access the radiator. Storage Compartments: Exterior- (1) Lighted storage compartments with door and lock 54” long minimum. Box is located driver’s side behind rear axle. Switch Panel: Shall be mounted to the left of the driver with switches for the electrical components. Rocker type switches are to be supplied. The switches shall provide illuminated lenses, international symbols and labeling for the appropriate functions. The switches are to be rated at 20 amps at 12-volts DC. Control panel illumination to be controlled by the headlamp switch rheostat. Switches are to be angled at 45° for driver accessibility. Visibility: The design of this bus shall be such that the seated driver shall be able to view the ground by direct visibility along a parallel line 9' forward of the front bumper the entire width of the bus. For the purpose of complying with this requirement, test to be conducted in accordance with SAE J-941 utilizing the dimensions of a 95th percentile adult male. Window: Driver's Area- Split window transit style with tempered tinted glass and latch. Windshield: 4-piece flat tinted glass set in rubber. Each front glass shall be a minimum of 39" wide x 35" high. The windshield shall be designed for maximum driver visibility in all directions. Windshield shall be as low as possible to allow maximum downward view in front of vehicle. Total daylight opening of the windshield is 3,133 sq. in. Windshield Washer: Washer reservoir to be one gallon capacity and accessible through interior access door located at the top of the stepwell. Electric operated with wiper arm spray reservoir (1) gallon capacity. Windshield Wipers: (2) Bottom mounted electrically operated with parallelogram type arms with variable speed and intermittent feature. Access to wiper motors to be provided through hinged exterior access panels.
MAB CONVERSION PACKAGE
Air Brake Inlet (1) external quick connect air line fitting to allow external air line to be attached to bus while secured in parking bay to maintain air brake/air ride system pressure. A/C Heating System: (4) 13,500 BTU (each) roof mounted air conditioner/heating units. 110 volt. Roof sections shall be reinforced where units are mounted. Each climate control unit shall be wired separately and protected with individual circuit breaker in the electrical control panel. Battery Charger: 20 amp, exterior hookup battery charger shall be supplied. Charger must be designed to maintain vehicle’s batteries at peak charge while vehicle is not being operated. Exterior battery charge readout monitor shall be located near the battery charger exterior hookup location. Carbon Monoxide Alarm: (2) carbon monoxide monitor alarms shall be installed (1) at the rear of the bus and (1) at the nurse’s station to warn of unsafe buildup of CO in the bus cabin. Ceiling Grab Rails: Stainless steel ceiling grab rails shall be located front to back on each side of the bus aisle. Curtain A non-light penetrating sliding curtain shall be installed immediately behind the driver from floor to ceiling and from side to side to keep all light from reaching the driver’s area during vehicle operation at night. Electrical System: Shall be a 120/240 volt rated system. A waterproof interior service panel junction box. Box shall be a 125 Amp rated capacity with UL Listed resetting type circuit breakers. Each of the AC/Heat units shall be protected with an individual circuit breaker. All of the A/C electrical system is installed using EPM 12ga. 3 conductor (10\3) multi-stranded boat wire 600 volt UL approved. All wire is color coded and grounded throughout the system. Ten (10) interior quad outlets will be provided. Locations will be determined by interior layout. Electrical: Shoreline A shoreline electrical connection shall be provided on the exterior of the vehicle to allow connection to an existing power source such as a building or other generator such as a military generator to operate all on-board options. Feature will allow vehicle to remain connected to external power source for and unlimited amount of time. Vehicle owner shall be responsible for installation of 50 amp shoreline service connection and shoreline wiring cable. Manufacturer shall supply connection fitting to vehicle shoreline plug. Exhaust Fan: Interior (2) air exhaust fans in the interior floor area to exhaust interior air as exterior air is brought into the vehicle from air conditioning/heating units or through roof escape hatch vents Floor Covering Floor covering shall be Altro Transflor Model TFCR2730. Floor covering shall anti germ/virus properties. Generator: Diesel powered 20 KW 175 watt Martin Diesel Generator. Generator will be equipped with air bag shock isolators to decrease vibration. Fuel source shall come from the main vehicle fuel tank. Generator shall be mounted on a slide out tray for easy servicing. Dual locks shall lock the generator in the stowed position when the tray is returned to normal operating position. Generator compartment shall have a sealed ball bearing slide out tray for easy access for servicing generator. Compartment to be insulated to reduce heat and noise transferred to interior # of the vehicle. Generator exhaust shall exit left side of the vehicle. Generator Controls: Generator start, run, stop, preheat switch and hour meter shall be located within easy reach of driver. Exterior generator service controls shall be located in the generator compartment. Intercom System: David Clark radio communications/intercom system with headsets at the driver seat and each attendant seat and at the nurse’s station. The headsets at the driver seat and at the nurse’s station should have the ability to talk on the intercom as well as the dual radio interface communications system that will be installed by owning agency. Intravenous Fluid Hangers: Twelve (12) Recessed ceiling mounted IV Hangers. IV hangers to be mounted at the head of each stretcher position. Lighting: LED Ceiling Lights - Ceiling mounted LED operational recessed lighting located in approximately every other ceiling panel location throughout bus and over nurse’s station Exterior Underfloor Lights - (10) waterproof underfloor exterior LED lights to illuminate the area around and under the vehicle. Scene Lights - (5) 110v roof mounted scene lights, (2) on each side of vehicle and (1) on the rear of the vehicle. Havis-Shield Model KR-1433 Exterior: NFPA Emergency Lighting: Zone A: Upper – (1) Whelen 60” LED Flush Mount 4500 Series Light Bar. Outer four light bar lens should be red. Center two light bar lens should be clear. Zone B: Upper - (4) Whelen NFPA 1901 Compliant 90RR5FRR 9”x7” 900 Series Red Super LED light heads. Lower - (3) Whelen NFPA 1901 Compliant 60R02FRR 6”x4” 600 Series Red Super LED light heads. Front most side lights should be mounted as close to the front edge of the bus as possible to provide intersection warning ability. Zone C: (2) Whelen NFPA 1901 Compliant 90RR5FRR 9”x7” 900 Series Red Super LED light head. (2) Whelen NFPA 1901 Compliant 90AA5FAR 9”x7” 900 Series Amber Super LED light head. (1) red and (1) amber 900 Series light head should be mounted high. (1) red and (1) amber 900 series light head should be mounted lower. Positioning of the red and amber lights should be in opposite corners from one another. Flash pattern should resemble the flashing pattern of a railroad crossing sign that is activated. (2) 60K000XR 4”x6” clear LED Loading lights. Lights to operate from a switch or when the vehicle is in reverse. (2) Whelen PS00FRR LED Light (Red) and (2) Whelen PS00FAR LED Light (Amber) should be mounted on left rear and right rear of bus just above bumper. Placement of lights from driver side to passenger side facing rear should be Red-Amber and Amber-Red. Red lights should flash simultaneously and amber lights should flash simultaneously (alternately from red). Nurse’s Station Oxygen System: Oxygen External Connection: Refrigerator: (1) Refrigerator/Freezer 110v, approximate size 59”H x 23”W x 25”D shall be installed adjacent to mid-body attendant seating for storage of medicine, water, etc.. Refrigerator shall be powered by both shore power or generator power. Seats: Attendants (6) Mid-High Back Flip Up Attendant Seats shall be provided. All seats shall have restraining belts for attendants. Seats: Rehab (12) Wall mounted flip down seats for firefighter rehab, walking wounded or attendants. When stretchers are removed seats can be folded down to allow additional seating. (8) additional flip down seats are available with a floorplan change. (NOT AVAILABLE WITH STAINLESS STEEL STRETCHER PANS). Sliding Stretcher Receiver: Stretchers shall be carried into the vehicle and set into the sliding stretcher tray assembly. The sliding stretcher tray assemblies are then slid and locked into place to prevent movement of stretchers. Locking pins shall eliminate any horizontal movement of the patient stretcher tray assembly.The stretcher tray assembly shall have a vertical elimination bracket on each end of the assembly to prevent the stretcher from moving in a vertical movement after the stretcher has been stowed.Sliding Stretcher Assembly Tray Part Number MAB-62550 only. Snow Chains Vehicle shall be equipped with OnSpot automatic snow chains. The switch to operate the snow chains shall be within easy reach of the driver. Storage Compartments Interior: (6) Six stainless steel medical storage compartments with pull out doors 19.5”W x 15.75”T x 18”D. Compartments are located under attendant seats. All compartments are made out of laminated wood covered with stainless steel cover. Stretcher Pans Stainless steel stretcher pans to collect body fluids and to keep those fluids from dropping down on patients below. Pan includes hose hookup for ease of cleaning. Stretchers: (18) Twenty adjustable headrest type non-folding stretchers, 74” x 19”. Stretchers shall have a load limit weight of 350 pounds each. Stretchers STRYKER Rolling: (2) Stryker rolling gurney type stretchers in located in lower/rear most position on each side of vehicle. Stretcher Mounting System: Stretchers shall be mounted in a “stacked assembly” method. Three (3) stretchers receiver tray assemblies shall evenly spaced from above floor level to approximately 58” off the floor.. Stretcher Tray Assembly: Optional - Stainless steel stretcher tray assembly shall be provided for each stretcher. Tray shall slide in and out on sliding stretcher assembly. Tray construction shall have all sides of the stretcher tray assembly sloping toward the patient’s feet area where a drain plug and discharge cleanout connection is located. (2) two removable stainless steel mid-stretcher support braces shall be supplied for each stretcher to give added support to the center section of the patient’s stretcher when the stretcher is in the stowed position. Wheelchair Tiedown Positions: Floor tracking shall be installed and spaced so that, if necessary, wheelchair occupants can utilize the floor track for a wheelchair tie-down system. Wheelchair Tiedown System: (8) wheelchair tiedown kits shall be supplied, SureLok Model FF627S-4C. WARRANTY MAB Conversion (2) Two Year - Unlimited Miles Generator (2) Two Year 1500 Hours Rooftop Heat/Air Conditioning (2) Two Year - Unlimited Mileage Basic IC Vehicle (1) One Year - Unlimited Miles IC Body * (5) Five Year - Unlimited Miles IC Body ** (1) One Year / 12,000 miles IC Drivetrain *** (4) Four Year / 48,000 Miles IC Engine (5) Five Year - Unlimited Miles Allison Transmission (2) Two Year - Unlimited Miles Towing **** (5) Five Year / 150,000 Miles |
|||
|
|||
|
|||
________________________________________________________________________ |
|||
|
|||
Sartin Services, Inc. 6116 Old Mendenhall Road Archadale, NC 27263 (888) 524-5505 Toll Free (336) 889-4498 Fax |